pool balustrade framed glass balustrade and balcony balustrades prices
In construction projects, the protective height of pool balustrade framed glass balustrade and balcony balustrades prices is a very basic but easy to confuse issue, but as long as you are familiar with the requirements of the specifications and do a good job of summarizing and summarizing, it is a very simple matter.guardrail
1. Several figures related to the protection height:
1. "1.05"
(1) Balcony, veranda, indoor corridor, inner patio, roof and outdoor stairs, etc., when the height of the sky is below 24.0m, the height of the railing should not be less than 1.05m. (Note: refer to Article 6.7.3 of "Uniform Standard for Civil Building Design" (GB50352-2019))
(2) When the height of the steps at the public entrance and exit exceeds 0.70m and the side faces are empty, protective facilities shall be set up, and the net height of the protective facilities shall not be lower than 1.05m. (Note: refer to Article 6.1.2 of "Code for Residential Design" (GB50096-2011), this article is a strong one)
(3) The clear height of the pool balustrade framed glass balustrade and balcony balustrades prices in the air-side areas such as the outer corridor, the inner patio and the roof of the upper person shall not be lower than 1.05m on the sixth floor and below. (Note: refer to Article 6.1.3 of "Code for Residential Design" (GB50096-2011), this article is a strong one)
(4) When the length of the railing in the horizontal section of the stairs is greater than 0.50m, the height of the handrail shall not be less than 1.05m. (Note: refer to Article 6.3.2 of "Code for Residential Design" (GB50096-2011), this article is a strong one)
2. "1.10"
(1) Balcony, veranda, indoor corridor, inner patio, roof and outdoor stairs, etc., when the height of the sky is 24.0m and above, the height of the railing should not be less than 1.1m. (Note: refer to Article 6.7.3 of "Uniform Standard for Civil Building Design" (GB50352-2019); Article 8.1.6 of "Code for Design of Primary and Middle Schools" (GB50099-2011) also has similar expressions, this article is a strong one)
(2) The clear height of the pool balustrade framed glass balustrade and balcony balustrades prices in the air-facing places such as the outer corridor, the inner patio and the roof of the upper person shall not be lower than 1.10m on the seventh floor and above. (Note: refer to Article 6.1.3 of "Code for Residential Design" (GB50096-2011), this article is a strong one)
3. "1.20"
(1) The height of the pool balustrade framed glass balustrade and balcony balustrades prices on the roof and the open atrium of buildings such as traffic, business, hotels, hospitals, schools, etc. should not be less than 1.2m. (Note: refer to Article 6.7.3 of "Uniform Standard for Civil Building Design" (GB50352-2019))
4. "1.30"
(1) The outer corridors, indoor corridors, inner patios, balconies, roofs, platforms, stands and outdoor stairs of nurseries and kindergartens should be equipped with protective pool balustrade framed glass balustrade and balcony balustrades prices, and the clear height should not be less than 1.30m. (Note: Please refer to Article 4.1.9 of "Code for Architectural Design of Nurseries and Kindergartens" (JGJ39-2016) (2019 Edition), which is a strong article)
5. "0.8"
(1) The clear height of the window sills of the external windows of public buildings from the ground shall not be lower than 0.8m, otherwise protective facilities shall be set up, and the height of the protective facilities shall not be lower than 0.8m from the ground. (Note: refer to Article 6.11.6 of "Uniform Standard for Civil Building Design" (GB50352-2019))
(2) The protective facilities installed on the building curtain wall shall comply with the provisions of Article 6.11.6 of this standard. (Note: refer to Article 6.12.4 of "Uniform Standard for Civil Building Design" (GB50352-2019))
6. "0.9"
(1) The clear height of the window sill of the external windows of the residential building from the ground shall not be lower than 0.9m, otherwise protective facilities shall be set up, and the height of the protective facilities shall not be lower than 0.9m from the ground. (Note: refer to Article 6.11.6 of "Uniform Standard for Civil Building Design" (GB50352-2019))
(2) For the external windows of common parts such as stairwells and elevator halls, if there is no balcony or platform outside the window, and the clear height of the window sill from the floor and the ground is less than 0.90m, protective facilities shall be provided. (Note: refer to Article 6.1.1 of "Code for Residential Design" (GB50096-2011), this article is a strong one)
(3) The protective facilities installed on the building curtain wall shall comply with the provisions of Article 6.11.6 of this standard. (Note: refer to Article 6.12.4 of "Uniform Standard for Civil Building Design" (GB50352-2019))
(4) There is no balcony or platform outside the window. When the clear height of the window sill from the floor and the ground is less than 0.90m, protective facilities should be installed. (Note: refer to Article 5.8.1 of "Code for Residential Design" (GB50096-2011), this article is a strong one)
(5) For the building windows of nurseries and kindergartens, when the height of the window sill from the floor is lower than 0.90m, protective measures should be taken. (Note: refer to Article 4.1.5 of "Code for Architectural Design of Nurseries and Kindergartens" (JGJ39-2016) (2019 Edition))
(6) The height of the window sill should not be less than 0.90m. (Note: Please refer to Article 8.1.5 of "Code for Design of Primary and Secondary Schools" (GB50099-2011), this article is a strong one)
Comments: (1) The height of the railing is determined according to the monitoring data of the national physique and the necessary safety reserves. The conventional protective height is roughly 1.05 meters at the lower part and 1.10 meters at the height; however, the public places of schools, businesses, hospitals, hotels, transportation and other buildings near the atrium are more dangerous, and the height of the pool balustrade framed glass balustrade and balcony balustrades prices is further increased to 1.20 meters; while the nursery school , The maximum protective height of the railing in the kindergarten is 1.30 meters, mainly considering the situation that infants and young children are active, easy to climb, and adults hold the baby to stand. (2) Protection measures of 0.8m or 0.9m need to be set for external windows and curtain wall windows without balconies or platforms. The main purpose is to prevent people from falling from high altitudes after the glass is impacted. The practice of adding laminated glass to the frame. "Residential Design Code" (GB50096-2011) stipulates that the mesa, horizontal pool balustrade framed glass balustrade and balcony balustrades prices and other treads that are less than 0.45m away from the floor (ground) surface are likely to cause unconscious climbing, and should not be included in the clear height of the window sill.
2. Other numbers:
1. "0.11"
(1) For the pool balustrade framed glass balustrade and balcony balustrades prices of residences, nurseries, kindergartens, primary and secondary schools and other special activity places for children, when vertical rods are used as pool balustrade framed glass balustrade and balcony balustrades prices, the net spacing of the rods should not be greater than 0.11m. (Note: refer to Article 6.7.4 of "Uniform Standard for Civil Building Design" (GB50352-2019), this article is a strong one)
(2) The protective pool balustrade framed glass balustrade and balcony balustrades prices must be constructed to prevent children from climbing, and the clear distance between the vertical members of the pool balustrade framed glass balustrade and balcony balustrades prices should not be greater than 0.11m. (Note: refer to Article 6.1.3 of "Code for Residential Design" (GB50096-2011), this article is a strong one)
(3) The clearance between the vertical members of the stair railing should not be greater than 0.11m. (Note: refer to Article 6.3.2 of "Code for Residential Design" (GB50096-2011), this article is a strong one)
2. "0.09"
(1) The outer corridors, indoor corridors, inner patios, balconies, roofs, platforms, stands and outdoor stairs of nurseries and kindergartens should be equipped with protective pool balustrade framed glass balustrade and balcony balustrades prices. The protective pool balustrade framed glass balustrade and balcony balustrades prices must be constructed to prevent children from climbing and passing through. When vertical rods are used as pool balustrade framed glass balustrade and balcony balustrades prices, the net distance of the rods should not be greater than 0.09m. (Note: Please refer to Article 4.1.9 of "Code for Architectural Design of Nurseries and Kindergartens" (JGJ39-2016) (2019 Edition), which is a strong article)
Comments: When vertical rods are used as pool balustrade framed glass balustrade and balcony balustrades prices, the clear spacing requirements of the rods are all strong strips, so special attention is required. The conventional value is 0.11 meters, but the value of nurseries and kindergartens is further reduced to 0.09 meters, mainly to prevent the head or body of infants and young children from getting stuck in the gap of the railing, causing safety accidents.
Three, you need to know a few common sense:
(1) The height of the railing should be calculated from the ground or roof of the building where it is located to the vertical height of the top surface of the railing. When the width of the bottom surface is greater than or equal to 0.22m and the height is less than or equal to 0.45m, it should be calculated from the top surface of the stepable part. . (Note: refer to Article 6.7.3 of "Uniform Standard for Civil Building Design" (GB50352-2019))
(2) Horizontal load of pool balustrade framed glass balustrade and balcony balustrades prices: The current national standard "Code for Loads of Building Structures" GB50009 stipulates that the load of horizontal thrust at the top of pool balustrade framed glass balustrade and balcony balustrades prices is 1.0kN/m. Because students are frolicing or evacuating in emergency, the number of people who squeeze and push the pool balustrade framed glass balustrade and balcony balustrades prices in a concentrated manner often exceeds 2 people/m, and the GB50099 Design Specification for Primary and Secondary Schools is increased to 1.5kN/m.
Fourth, the height of the protective railing during the construction process
The above is the height of the protective pool balustrade framed glass balustrade and balcony balustrades prices required by the building design specifications, but during the construction process, what is the protective height of the construction site at the edge or near the opening of the construction site?
The answer is: the normal value is not less than 1.2m, but there is an exception, the protective height of the elevator shaft protection door should not be less than 1.5m. The above values refer to "Technical Specifications for Safety of Construction at Heights" (JGJ80-2016).